Pd fcc EMT_Asap_Standard_JacobsenStoltzeNorskov_1996_Pd__MO_066802556726_001 3.8789845258 Optimization terminated successfully. Current function value: -15.600806 Iterations: 71 Function evaluations: 187 C11 = 217.577723 +/- 0.007336 GPa C12 = 162.188615 +/- 0.005187 GPa C44 = 74.502825 +/- 0.001834 GPa B = 180.651651 +/- 0.004235 GPa