!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!! !!!!! !!!!! VERIFICATION CHECK: vc-dimer-continuity-c1 !!!!! !!!!! !!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Description: Determines whether a model has a continuous energy and first derivative, i.e. belongs to the C^1 continuity class, for all possible dimers. For a model supporting N species, there are N + N!/(2(N-2)! distinct dimers for all possible species combinations. (For example if N=3, there are 3+3!/2=6 dimers. If the species are A,B,C, the 6 dimers are AA, BB, CC, AB, AC, BC.) For each dimer, the equilibrium separation and cutoff are determined. The continuity across the cutoff is assessed. Then an analysis is performed to detect any discontinuities from half the equilibrium distance to the cutoff. Although the verification check only requires C^1 continuity to pass, continuity up to 3rd order is checked and reported. Author: Ellad Tadmor ----------------------------------------------------------------------------------------------------- Results for KIM Model : model_ArCHHeXe_BOP_AIREBO__MO_154399806462_001 Supported species : Ar C H He Xe ----------------------------------------------------------------------------------------------------- DIMER Ar--Ar ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.82759559e+00 -1.03236106e-02 35 71 none Cutoff separation: 1.02299967e+01 -2.22007891e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22007891e-16 yes 1st-Deriv 1.35529206e-10 yes 2nd-Deriv -4.13669388e-05 ** NO ** 3rd-Deriv 4.38028794e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.91380,10.23000] at 832 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-ArAr.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-ArAr.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-ArAr.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-ArAr.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER C--C ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 1.32550000e+00 -6.20984351e+00 28 56 none Cutoff separation: 2.00000000e+00 0.00000000e+00 26 28 none C u t o f f S m o o t h n e s s value continuous Energy 0.00000000e+00 yes 1st-Deriv -4.84683416e-08 yes 2nd-Deriv -1.62408696e+02 ** NO ** 3rd-Deriv 6.83059323e+02 ** NO ** C o n t i n u i t y Checking continuity for r = [0.66275,2.00000] at 134 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-CC.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-CC.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-CC.dat") ==> Suspected discontinuity encountered at r=1.67275000e+00 (|T^5| = 4.02821578e+01) ==> Suspected discontinuity encountered at r=1.68275000e+00 (|T^5| = 1.63021586e+02) ==> Suspected discontinuity encountered at r=1.69275000e+00 (|T^5| = 2.46988238e+02) ==> Suspected discontinuity encountered at r=1.70275000e+00 (|T^5| = 1.66002876e+02) ==> Suspected discontinuity encountered at r=1.71275000e+00 (|T^5| = 4.17568461e+01) Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-CC.dat") ==> Suspected discontinuity encountered at r=1.67275000e+00 (|T^5| = 1.68944590e+02) ==> Suspected discontinuity encountered at r=1.68275000e+00 (|T^5| = 6.35655282e+02) ==> Suspected discontinuity encountered at r=1.69275000e+00 (|T^5| = 8.89706538e+02) ==> Suspected discontinuity encountered at r=1.70275000e+00 (|T^5| = 5.48531636e+02) ==> Suspected discontinuity encountered at r=1.71275000e+00 (|T^5| = 1.25590373e+02) ----------------------------------------------------------------------------------------------------- DIMER H--H ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 7.46099609e-01 -4.50630160e+00 28 56 none Cutoff separation: 1.69999999e+00 -1.21001106e-15 26 28 none C u t o f f S m o o t h n e s s value continuous Energy -1.21001106e-15 yes 1st-Deriv 2.19653505e-07 yes 2nd-Deriv -1.99198063e+01 ** NO ** 3rd-Deriv 9.45540002e+01 ** NO ** C o n t i n u i t y Checking continuity for r = [0.37305,1.70000] at 133 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-HH.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-HH.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-HH.dat") ==> Suspected discontinuity encountered at r=1.07304980e+00 (|T^5| = 7.78829333e+00) ==> Suspected discontinuity encountered at r=1.08304980e+00 (|T^5| = 3.14513253e+01) ==> Suspected discontinuity encountered at r=1.09304980e+00 (|T^5| = 4.76051531e+01) ==> Suspected discontinuity encountered at r=1.10304980e+00 (|T^5| = 3.20075747e+01) ==> Suspected discontinuity encountered at r=1.11304980e+00 (|T^5| = 8.06543438e+00) Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-HH.dat") ==> Suspected discontinuity encountered at r=1.07304980e+00 (|T^5| = 2.87970932e+01) ==> Suspected discontinuity encountered at r=1.08304980e+00 (|T^5| = 1.13185550e+02) ==> Suspected discontinuity encountered at r=1.09304980e+00 (|T^5| = 1.66580001e+02) ==> Suspected discontinuity encountered at r=1.10304980e+00 (|T^5| = 1.08790403e+02) ==> Suspected discontinuity encountered at r=1.11304980e+00 (|T^5| = 2.65994535e+01) ----------------------------------------------------------------------------------------------------- DIMER He--He ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 2.55921347e+00 -8.78971855e-04 32 64 none Cutoff separation: 6.83999249e+00 -2.22062281e-16 27 29 none C u t o f f S m o o t h n e s s value continuous Energy -2.22062281e-16 yes 1st-Deriv 5.91523875e-11 yes 2nd-Deriv -7.87842597e-06 ** NO ** 3rd-Deriv 1.24769115e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.27961,6.83999] at 557 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-HeHe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-HeHe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-HeHe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-HeHe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER Xe--Xe ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 4.55719592e+00 -1.98199536e-02 36 72 none Cutoff separation: 1.21799972e+01 -2.22035032e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22035032e-16 yes 1st-Deriv 1.57740002e-10 yes 2nd-Deriv -5.60248463e-05 ** NO ** 3rd-Deriv 4.98262765e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [2.27860,12.18000] at 991 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-XeXe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-XeXe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-XeXe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-XeXe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER Ar--C ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.82198328e+00 -5.41826418e-03 35 70 none Cutoff separation: 1.02149955e+01 -2.21752248e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.21752248e-16 yes 1st-Deriv 9.82724309e-11 yes 2nd-Deriv -2.17749438e-05 ** NO ** 3rd-Deriv 2.30910350e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.91099,10.21500] at 831 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-ArC.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-ArC.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-ArC.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-ArC.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER Ar--H ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.40106000e+00 -3.93439383e-03 33 66 none Cutoff separation: 9.08999528e+00 -2.22129612e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22129612e-16 yes 1st-Deriv 9.41852121e-11 yes 2nd-Deriv -1.99675157e-05 ** NO ** 3rd-Deriv 2.37949481e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.70053,9.09000] at 739 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-ArH.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-ArH.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-ArH.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-ArH.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER Ar--He ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.19340453e+00 -3.01233517e-03 33 66 none Cutoff separation: 8.53499494e+00 -2.22066131e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22066131e-16 yes 1st-Deriv 8.77597638e-11 yes 2nd-Deriv -1.73408571e-05 ** NO ** 3rd-Deriv 2.20085552e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.59670,8.53499] at 694 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-ArHe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-ArHe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-ArHe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-ArHe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER Ar--Xe ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 4.19239575e+00 -1.43043169e-02 34 69 none Cutoff separation: 1.12049969e+01 -2.22220568e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22220568e-16 yes 1st-Deriv 1.45725127e-10 yes 2nd-Deriv -4.77767070e-05 ** NO ** 3rd-Deriv 4.61880191e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [2.09620,11.20500] at 911 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-ArXe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-ArXe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-ArXe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-ArXe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER C--H ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 1.09000001e+00 -4.52579956e+00 25 51 none Cutoff separation: 1.80000000e+00 0.00000000e+00 26 28 none C u t o f f S m o o t h n e s s value continuous Energy 0.00000000e+00 yes 1st-Deriv -4.80992603e-08 yes 2nd-Deriv -4.61113340e+01 ** NO ** 3rd-Deriv 1.80364846e+02 ** NO ** C o n t i n u i t y Checking continuity for r = [0.54500,1.80000] at 126 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-CH.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-CH.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-CH.dat") ==> Suspected discontinuity encountered at r=1.27500000e+00 (|T^5| = 1.33144027e+01) ==> Suspected discontinuity encountered at r=1.28500000e+00 (|T^5| = 5.36467196e+01) ==> Suspected discontinuity encountered at r=1.29500000e+00 (|T^5| = 8.09940164e+01) ==> Suspected discontinuity encountered at r=1.30500000e+00 (|T^5| = 5.43011051e+01) ==> Suspected discontinuity encountered at r=1.31500000e+00 (|T^5| = 1.36395166e+01) Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-CH.dat") ==> Suspected discontinuity encountered at r=1.27500000e+00 (|T^5| = 3.57813322e+01) ==> Suspected discontinuity encountered at r=1.28500000e+00 (|T^5| = 1.36938630e+02) ==> Suspected discontinuity encountered at r=1.29500000e+00 (|T^5| = 1.95695790e+02) ==> Suspected discontinuity encountered at r=1.30500000e+00 (|T^5| = 1.23713848e+02) ==> Suspected discontinuity encountered at r=1.31500000e+00 (|T^5| = 2.91780311e+01) ----------------------------------------------------------------------------------------------------- DIMER C--He ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.18779222e+00 -1.58099994e-03 33 66 none Cutoff separation: 8.51999303e+00 -2.22155354e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22155354e-16 yes 1st-Deriv 6.37029339e-11 yes 2nd-Deriv -9.13330675e-06 ** NO ** 3rd-Deriv 1.16121492e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.59390,8.51999] at 693 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-CHe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-CHe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-CHe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-CHe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER C--Xe ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 4.18678344e+00 -7.50750595e-03 34 68 none Cutoff separation: 1.11899958e+01 -2.22254729e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22254729e-16 yes 1st-Deriv 1.05718726e-10 yes 2nd-Deriv -2.51425203e-05 ** NO ** 3rd-Deriv 2.43390460e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [2.09339,11.19000] at 910 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-CXe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-CXe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-CXe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-CXe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER H--He ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 2.76686895e+00 -1.14802014e-03 32 64 none Cutoff separation: 7.39499289e+00 -2.22462634e-16 27 29 none C u t o f f S m o o t h n e s s value continuous Energy -2.22462634e-16 yes 1st-Deriv 6.25847993e-11 yes 2nd-Deriv -8.80337500e-06 ** NO ** 3rd-Deriv 1.28954045e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.38343,7.39499] at 602 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-HHe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-HHe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-HHe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-HHe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER H--Xe ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.76586018e+00 -5.45146640e-03 35 70 none Cutoff separation: 1.00649956e+01 -2.21920536e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.21920536e-16 yes 1st-Deriv 1.00079906e-10 yes 2nd-Deriv -2.25662494e-05 ** NO ** 3rd-Deriv 2.42868021e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.88293,10.06500] at 819 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-HXe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-HXe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-HXe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-HXe.dat") ... No discontinuities found. ----------------------------------------------------------------------------------------------------- DIMER He--Xe ----------------------------------------------------------------------------------------------------- E n e r g y E x t r e m a distance energy #iter #fn-calls warnings Equilibrium separation: 3.55820469e+00 -4.17386887e-03 33 66 none Cutoff separation: 9.50999521e+00 -2.22215381e-16 28 30 none C u t o f f S m o o t h n e s s value continuous Energy -2.22215381e-16 yes 1st-Deriv 9.27430595e-11 yes 2nd-Deriv -1.93531502e-05 ** NO ** 3rd-Deriv 2.20442731e-05 ** NO ** C o n t i n u i t y Checking continuity for r = [1.77910,9.51000] at 774 points (Delta r = 0.01000) Local edge detection based on a normalized 5th-order local difference formula T^5 is used to determine the presence of discontinuities. The tolernace is |T^5|>1.00000. (For details see Anne Gelb and Eitan Tadmor, J. Sci. Comp., 28:279-306, 2006.) Checking Energy (energy vs. distance in file "dimer-energy-HeXe.dat") ... No discontinuities found. Checking 1st-Deriv (1st-deriv vs. distance in file "dimer-energy-deriv-1-HeXe.dat") ... No discontinuities found. Checking 2nd-Deriv (2nd-deriv vs. distance in file "dimer-energy-deriv-2-HeXe.dat") ... No discontinuities found. Checking 3rd-Deriv (3rd-deriv vs. distance in file "dimer-energy-deriv-3-HeXe.dat") ... No discontinuities found. ===================================================================================================== SUMMARY of Model Continuity Results Across All Dimers: continuous ----------------------------- Energy yes 1st-Deriv yes 2nd-Deriv ** NO ** 3rd-Deriv ** NO ** ===================================================================================================== Continuity must be C^1 or higher to pass this verification check. Grade: P Comment: The model is C^1 continuous. This means that the model has continuous energy and continuous first derivative.